Necessary cookies provide basic functions of our website. Without these cookies you cannot use e.g. shop functions or logins. The website will therefore not function properly without these cookies.
name | Hosts | description | Procedure | type |
---|---|---|---|---|
dv_t3_consent_management | Matthies.comSaves your cookie and tracking settings If you delete this cookie, you will have to set the settings again. | .1 year | HTTP | |
activeCartName | Matthies | Saves shopping cart information | Close the browser | HTTP |
activeCartId | Matthies | Saves shopping cart information | Close the browser | HTTP |
hide-katy-renovation-notice | Matthies | remembers if certain messages have already been displayed | 6 months | HTTP |
Diese Cookies sorgen ggf. dafür, dass in Statistiken gesammelt wird, welche Seiten Sie besucht haben und wofür Sie sich interessieren. Das dient dazu, Ihnen z.B. passende Werbung anzuzeigen. Diese Statistiken wirken ggf. auch über diese Webseite hinaus. Genaue Angaben finden Sie unter „Mehr dazu..“
Name | Hosts | Beschreibung | Ablauf | Typ |
---|---|---|---|---|
mietkauf | Matthies | zählt Aufrufe der Mitkaufseiten | 6 Monate | HTTP |
You are here: Home » Article details 'RADIATOR JMP'
Wasserkühler JMP
>>> Optimale Kühlleistung und Haltbarkeit <<<
Vorteile JMP:
- Bessere Kühlleistung durch spezielle Lamellentechnik
- Ideal für Motoren mit hoher, thermischer Belastung
- Handgeschweißt, poliert und druckgeprüft
- Kann direkt gegen den OE Kühler getauscht werden
Läuft der Motor, wird automatisch Reibung und Hitze erzeugt. Deswegen muss der Motor bestmöglich gekühlt werden, um eine Überhitzung zu vermeiden.
Wasserkühler bestehen aus Rohren und dazwischen liegenden Lamellen. Durch diese Rohre fließt die Kühlflüssigkeit. Eine kontinuierliche Lufströmung kühlt die Flüssigkeit ab und verhindert somit die Überhitzung des Motors.
Wasserkühler-Varianten:
- Mechanisch gesteckter Kühler
- Gelöteter Kühler
Mechanisch gesteckter Kühler:
- Kosten- und energiesparende Produktion
- Runde Rohre vollständig durch die Lamellen gesteckt
- Kleiner Luftspalten zwischen Rohren und Lamellen
- Geringere Wärmeübertragung / Kühlleistung
Gelöteter Kühler:
- Rohre und Lamellen werden im Öfen gelötet
- Erschaffung einer metallischen Verbindung
- Optimale Wärmeübertragung
- Abgeflachte Rohre
- Größere Kühlfläche
- Bis zu 60% mehr Kühlleistung
Water cooler JMP
>>> Optimum cooling performance and durability <<<
Advantages of JMP:
- Better cooling performance thanks to special fin technology
- Ideal for engines with high thermal loads
- Hand-welded, polished and pressure-tested
- Can be replaced directly with the OE radiator
When the engine is running, friction and heat are automatically generated. The engine must therefore be cooled as well as possible to prevent overheating.
Water radiators consist of pipes with fins in between. The coolant flows through these pipes. A continuous flow of air cools the liquid and thus prevents the engine from overheating.
Water cooler variants:
- Mechanically plugged radiator
- Brazed radiator
Mechanically plugged cooler:
- Cost- and energy-saving production
- Round tubes fully inserted through the fins
- Smaller air gap between tubes and fins
- Lower heat transfer / cooling capacity
Brazed radiator:
- Tubes and fins are brazed in the furnace
- Creation of a metallic connection
- Optimum heat transfer
- Flattened tubes
- Larger cooling surface
- Up to 60% more cooling capacity
Article 776.01.24 RADIATOR JMP fits the following motorcycles: 66 | |||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Only show these manufacturers: << < 1 - 30 > >> View all | |||||||||||||||||||||||||||
Model | Code | typ | (from - to) | Year | Cylinder | Performance | |||||||||||||||||||||
| D | - | - | - | 2013 | 4 | 102 BHP, 75 kw | ||||||||||||||||||||
| D | - | - | - | 2014 | 4 | 102 BHP, 75 kw | ||||||||||||||||||||
| D | - | - | - | 2015 | 4 | 102 BHP, 75 kw | ||||||||||||||||||||
| 7 | PC41A | ZDC PC41A-07F000001 | ZDC PC41A-07F099999 | 2007 | 4 | 102 BHP, 75 kw | ||||||||||||||||||||
| 8 | PC41A | ZDC PC41A-08F050001 | ZDC PC41A-08F999999 | 2008 | 4 | 102 BHP, 75 kw | ||||||||||||||||||||
| 9 | PC41A | ZDC PC41A-09F075001 | - | 2009 | 4 | 102 BHP, 75 kw | ||||||||||||||||||||
| A | PC41A | ZDC PC41A-0AF090001 | ZDC PC41A-0AF099999 | 2010 | 4 | 102 BHP, 75 kw | ||||||||||||||||||||
| 7 | PC41B | ZDC PC41B-07F000001 | ZDC PC41B-07F099999 | 2007 | 4 | 34 BHP, 25 kw | ||||||||||||||||||||
| 8 | PC41B | ZDC PC41B-08F050001 | ZDC PC41B-08F099999 | 2008 | 4 | 34 BHP, 25 kw | ||||||||||||||||||||
| 9 | PC41B | ZDC PC41B-09F075001 | - | 2009 | 4 | 34 BHP, 25 kw | ||||||||||||||||||||
| A | PC41B | ZDC PC41B-0AF090001 | ZDC PC41B-0AF099999 | 2010 | 4 | 34 BHP, 25 kw | ||||||||||||||||||||
| B | PC41E | ZDC PC41E-0BF100001 | ZDC PC41E-0BF199999 | 2011 | 4 | 102 BHP, 75 kw | ||||||||||||||||||||
| C | PC41E | ZDC PC41E-0CF115001 | ZDC PC41E-0CF199999 | 2012 | 4 | 102 BHP, 75 kw | ||||||||||||||||||||
| D | - | - | - | 2013 | 4 | 102 BHP, 75 kw | ||||||||||||||||||||
| D | - | - | - | 2013 | 4 | 34 BHP, 25 kw | ||||||||||||||||||||
| D | - | - | - | 2014 | 4 | 102 BHP, 75 kw | ||||||||||||||||||||
| D | - | - | - | 2014 | 4 | 34 BHP, 25 kw | ||||||||||||||||||||
| D | - | - | - | 2015 | 4 | 102 BHP, 75 kw | ||||||||||||||||||||
| D | - | - | - | 2015 | 4 | 34 BHP, 25 kw | ||||||||||||||||||||
| 7 | PC41C | ZDC PC41C-07F000001 | ZDC PC41C-07F099999 | 2007 | 4 | 102 BHP, 75 kw | ||||||||||||||||||||
| 8 | PC41C | ZDC PC41C-08F050001 | ZDC PC41C-08F999999 | 2008 | 4 | 102 BHP, 75 kw | ||||||||||||||||||||
| 9 | PC41C | ZDC PC41C-09F075001 | - | 2009 | 4 | 102 BHP, 75 kw | ||||||||||||||||||||
| A | PC41C | ZDC PC41C-0AF090001 | ZDC PC41C0-AF099999 | 2010 | 4 | 102 BHP, 75 kw | ||||||||||||||||||||
| 7 | PC41D | ZDC PC41D-07F000001 | ZDC PC41D-07F099999 | 2007 | 4 | 34 BHP, 25 kw | ||||||||||||||||||||
| 8 | PC41D | ZDC PC41D-08F050001 | ZDC PC41D-08F999999 | 2008 | 4 | 34 BHP, 25 kw | ||||||||||||||||||||
| 9 | PC41D | ZDC PC41D-09F075001 | - | 2009 | 4 | 34 BHP, 25 kw | ||||||||||||||||||||
| A | PC41D | ZDC PC41D-0AF090001 | ZDC PC41D-0AF099999 | 2010 | 4 | 34 BHP, 25 kw | ||||||||||||||||||||
| B | PC41F | ZDC PC41F-0BF100001 | ZDC PC41F-0BF199999 | 2011 | 4 | 102 BHP, 75 kw | ||||||||||||||||||||
| C | PC41F | ZDC PC41F-0CF115001 | - | 2012 | 4 | 102 BHP, 75 kw | ||||||||||||||||||||
| B | PC41H | ZDC PC41H-0BF100001 | ZDC PC41H-0BF199999 | 2011 | 4 | 34 BHP, 25 kw |
2.0.0